| Properties | |
|---|---|
| adminMode | applicable=false |
| aggregateVflState | applicable=false |
| allowImmFamily | applicable=false |
| allowImmFamilyType | applicable=false |
| assemblyNo | applicable=false |
| assignedType | applicable=false |
| bootEpromVersion | applicable=false |
| chassisFPGenerationFP2 | applicable=false |
| chassisFPGenerationFP3 | applicable=false |
| chassisFPGenerationFP4 | applicable=false |
| chassisFPGenerationFP5 | applicable=false |
| chassisFPGenerationVFP | applicable=false |
| chassisRebootReqd | applicable=false |
| chassisRebootReqdReason | applicable=false |
| chassisSystemProfile | applicable=false |
| codeVersion | applicable=false |
| consoleAccess | applicable=false |
| coordinates | maximum=80 |
| defaultImmFamily | applicable=false |
| defaultImmFamilyType | applicable=false |
| equippedType | applicable=false |
| expectedAmps | applicable=false |
| forceMode | applicable=false |
| geoRedundancyMode | applicable=false |
| geoStandbyStatus | applicable=false |
| hwRev | applicable=false |
| isManaged | applicable=false |
| lastBootTime | applicable=false |
| lastSystemRebootReason | applicable=false |
| lastSystemRebootRouter | applicable=false |
| lastSystemRebootTime | applicable=false |
| lastSystemRebootUser | applicable=false |
| lastSystemRebootUserAddrType | applicable=false |
| lastSystemRebootUserAddress | applicable=false |
| lowTemperatureState | applicable=false |
| maxPowerBudget | applicable=false |
| mixedMode | applicable=false |
| numberOfOperSlots | applicable=false |
| numberOfmacaddresses | supported from=9.0.R4 |
| operImmFamily | applicable=false |
| operImmFamilyType | applicable=false |
| operMode | applicable=false |
| pfAexpectedAmps | applicable=false |
| pfBexpectedAmps | applicable=false |
| phyShelfRole | applicable=false |
| poeExternalPowerSupplyStatus | applicable=false |
| poeMainPseAvaliablePower | excluded chassis types=7210 SAS-S/Sx Virtual, 7210 SAS-Sx-48T-4SFP+, 7210 SAS-Sx-24T-4SFP+, 7210 SAS-Sx-22F-2C-4SFP+, 7210 SAS-Sx-46F-2C-4SFP+, 7210 SAS-S-24F-4SFP+, 7210 SAS-S-48F-4SFP+, 7210 SAS-Sx-64SFP+4CFP4 |
| poeMainPseConsumptionPower | excluded chassis types=7210 SAS-S/Sx Virtual, 7210 SAS-Sx-48T-4SFP+, 7210 SAS-Sx-24T-4SFP+, 7210 SAS-Sx-22F-2C-4SFP+, 7210 SAS-Sx-46F-2C-4SFP+, 7210 SAS-S-24F-4SFP+, 7210 SAS-S-48F-4SFP+, 7210 SAS-Sx-64SFP+4CFP4 |
| poeMaxPowerBudget | excluded chassis types=7210 SAS-S/Sx Virtual, 7210 SAS-Sx-48T-4SFP+, 7210 SAS-Sx-24T-4SFP+, 7210 SAS-Sx-22F-2C-4SFP+, 7210 SAS-Sx-46F-2C-4SFP+, 7210 SAS-S-24F-4SFP+, 7210 SAS-S-48F-4SFP+, 7210 SAS-Sx-64SFP+4CFP4 |
| poePowerSupplyMode | applicable=false |
| poePowerSupplyStatus | applicable=false |
| portTemplate | applicable=false |
| portTemplatePointer | applicable=false |
| pseAvaiablePower | applicable=false |
| pseCommittedPower | applicable=false |
| pseCommittedPowerHPoe | applicable=false |
| pseCommittedPowerPlus | applicable=false |
| pseCommittedPowerPlusPlus | applicable=false |
| pseCommittedPowerPoe | applicable=false |
| pseProvisionPowerPoe | applicable=false |
| pseProvisionPowerPoeHPoe | applicable=false |
| pseProvisionPowerPoePlus | applicable=false |
| pseProvisionPowerPoePlusPlus | applicable=false |
| pseProvisionedPower | applicable=false |
| runningConfigDir | applicable=false |
| runningDirectory | applicable=false |
| sasMode | default=mpls_mode |
| satClientDownDelay | applicable=false |
| satDynamicUplink | applicable=false |
| satFeatureLocalForward | applicable=false |
| satFeaturePtpTc | applicable=false |
| satPtpTc | applicable=false |
| satUplinkDistribution | applicable=false |
| serialNum | applicable=false |
| shelfAINS | applicable=false |
| shelfDesc | applicable=false |
| shelfIdCreate | applicable=false |
| shelfMacAddress | applicable=false |
| shelfName | write-access=no |
| shelfPresentType | applicable=false |
| shelfType | write-access=no |
| subNodePointer | applicable=false |
| subSysChassMemoryUsageHigh | applicable=false |
| swReposPointer | applicable=false |
| switchModel | applicable=false |
| syncE | applicable=false |
| sysPSMaxPoePowerBudget | applicable=false |
| systemPowerAvailable | applicable=false |
| systemPowerCommitted | applicable=false |
| systemPowerInUse | applicable=false |
| vChassisLocalVCSlot | applicable=false |